They are a wonderful implant for all you astra haters. For more information about astra tech implant system ev visit. Great to grow with and also handles the most complex treatments. If the fragment cannot be removed, go to step 4, removing the implant. At avtec dental we offer the highest quality dental handpieces and 24 hour inoffice handpiece repairs on all makes and models with over 18 years of dental handpiece experience. This highly versatile and flexible dental implant system enables successful outcomes. The top of this uniabutment is compatible with astra ev.
Astra ev compatible tpa screw for angled screw channels. Nobel biocare extends unrivaled range of edentulous treatment solutions with trefoil tiunite sets the standard for implant surface evidence. Included in t3 short surgical kit bsisk, tapered navigator surgical kit sgtikit, parallel walled navigator surgical kit sgkit. Please sign in to view price certain internal connection. If you want to learn more about how to get started with astra tech implant system ev go to. Large tray with surgical overlay highlighting procedural workflow. As a result, response times to your customer service requests may be delayed. Implant compatibility chart manufacturer implant titanium goldhue zirconia, including. Astra tech ev dental implant surgical and restorative. Minimum of components with maximum flexibility one connection, three sizes to minimize the number of components for simplified treatment planning and inventory management, the conical seal design implantabutment connection. Attach thread cleaner attach the appropriate thread cleaner into the restorative driver handle ev. All prices and product availability subject to change without prior notice. Astra tech osseospeed adjustable dental implant torque wrench.
Implant abutment torque and driver settings genieoss. Astra tech implant system ev how to assemble torque. The deeper thread design on astra tech implant ev improves the apical selfcutting properties and ensures better engagement between implant and osteotomy. Tutorial on handling of torque wrench ev and hex driver ev. These drivers go direct from a latchtype connection torque wrench to the locator implant abutment. The screws are used in conjunction with a special elliptical torx screwdriver which allows screwing from any angle up to 25.
The design philosophy of the astra tech implant system ev is. The anglebase ti base comes with an angulated screw, sku 19. The screws are used in conjunction with a special elliptical torx screwdriver which. Tpa screws for angled channels are used when it is necessary to correct the transocclusal screw channel angle of the restoration in order to improve its functionality and aesthetics.
Food and drug administration and state and local regulatory agencies. Salvin dental specialties implant dentistry procedure. This ti base is used for changing the screw access hole up to 25 degrees in any direction. The astra tech implant system ev is designed for ease of use and versatility in providing treatment solutions for your implant patients. Ti bases anglebase angulated ti bases astra ev dessusa. There is also a 4mm square head adaptor that accepts latch type drivers. To buy this product, please contact your local sales representative.
Astra tech implant system ev handling of torque wrench. Evseries dentsply astra tech osseospeed ev fseries nobelactive, nobelreplace conical. Available for tidesign, atlantis abutment in titanium and atlantis goldhue abutment. Allows the use of latch style drivers or burs in ratchet or torque wrenches with 4mm square connections. Astra tech implant system ev helps you deliver lifelong function and natural esthetics to your patients using a streamlined workflow that works perfectly for you. Atlantis titanium and zirconia abutments utilize the same torque and driver setting as the original. Abutment screw torque and driver manufacturer torque ncm driver 1520 24 25 30 35 45 titanium screwgold screw atlantis titanium and zirconia abutments utilize the same torque and driver setting as the original implant manufacturer astra 3. Implant driver conical connection rp 28 mm article number. There are about 12 different driver sizes used by the various implant systems in north america. The design philosophy of the astra tech implant system ev is based on the natural dentition utilizing a sitespecific, crowndown approach supported by an intuitive surgical protocol and a simple prosthetic workflow. Implant driver evgs 66 positioningaid 66 fixation system 67 sleeves 67 repair and retrival.
Astra tech osseospeed adjustable dental implant torque. Smartws implant driver torque wrench short stainless steel. Certain universal ratchet extension implant driver. Implant torque specification guide ensure you are applying the right amount of torque for your patients implant restoration. Screw torque requirements advanced dental technologies. Astra tech implant surgery used astra tech ev dental implant surgical and restorative drill kit. Repair procedures manual and product catalog astra tech. Manufacturer implant torque ncm torque settings driver. Implant compatibility chart manufacturer implant titanium goldhue zirconia, including atlantis crown abutment screwdriver biohorizons internal internal 3. Astra tech implant system torque wrench driver handle 25774. Each groove contains two engaging systems with 6 notches. If you are looking to reach someone directly, please call 18886496425. The deeper thread design on astra tech implant ev improves the apical selfcutting properties and.
Implant system compatible with astra tech osseospeed ev clc conic dyna pushin octalock kentec platon type iv pro sweden. Implant driver evgs the implant driver evgs can only engage into one single position of the implant. Oct 28, 2014 tutorial about how to assemble torque wrench ev with implant driver ev. If the item is subject to fda regulation, we will verify your status as an authorized purchaser of this item.
If you want to learn more about how to get started with astra tech implant system ev. Astra tech implant tidesigntm angled abutment direct abutmenr ball abutment locator tm abutment torque ncm manual small manual large manual manual 15 15 15 25 o 25 manual manual 15 15 15 o 20 o 25 only light finger force 510 ncm using a manual screwdriver or contra angle preset at 25 rpm and 510 ncm torque. The restoration screw was torque driven to the recommended 20 ncm for the osseospeed implant and 25 ncm for the ev implant with the torque wrench astra tech ab. The foundation of this evolutionary system remains. Astra tech implant system ev experienced user expand. Only light finger force 510 ncm using a manual screwdriver. Astra tech ev dental implant surgical and restorative drill. The two grooves on the shaft indicate the corresponding implant lengths 81115 mm and 69 mm. Titanium seating and peek in scanning area for optimal scanning results without spraying. Washtray and drilling protocol guide astra tech implant. Torcfit implant driver for ratchet, short, screwretained length 21mm stainless steel. Implant torque specification guide burdette dental lab. Implant driver conical connection rp 37 mm article number. Astra, biohorizons, imtec, intralock, sterioss, sybron, implant direct, perioseal, mis implant systems.
Astra tech implant system ev handling of torque wrench ev. Comparison of 3d displacements of screwretained zirconia. Keystone genesis and prima abutment screws are made of titanium and have a titanium nitride coating. Intended use in replacing missing teeth in single or multiple unit applications within the mandible or maxilla recommended to always place as wide an implant as indicated for immediate placement in extraction sites. Designed to be used with standard 4080 or adjustable torque 4081 wrenches. Find great deals on ebay for astra implant and straumann implant. This straight onepiece multiunit abutment has a fixed internal screw and is inserted using the 1.
In response to covid19, implant direct has taken several measures to protect the safety of our valued customers and employees. Abutment screw torque and driver manufacturer torque ncm driver. Use the torque wrench ev as a ratchet wrench and turn counterclockwise. Data were then collected for the crown position after torque application. Torque guide recommended tightening torque type of product torque ncm only light finger force 510 ncm using a manual screwdriver or contra angle preset at 25 rpm and 510 ncm torque. But could also be used manually by hand or with help of a hand wrench 4170. Oct 29, 2014 tutorial on handling of torque wrench ev and hex driver ev. Astra tech implant system allows for a strong and stable implant abutment connection. Implant impressions implant replica ev 25543 lab products uni abutment ev transfer 26249 impressionscylinders implant transfer ev long 25534 lab pin design ev 25528 direct abutment ev 3. Blx torque control device for ratchet, surgical stainless steel. Astra tech osseospeed adjustable dental implant torque wrench ref 24075 the sale of this item may be subject to regulation by the u. For those with 4mm square head drivers, they can be used with other torque wrenches with the purchase of an adaptor for about the same cost as a latch driver. Abutment bodyhead use the restorative driver handle together with the hex driver and the torque wrench ev to tighten the abutment screw to the recommended torque 25 ncm 1b.
The color coded implant driver makes implant installation quick, easy and efficient. Minimum of components with maximum flexibility one connection, three sizes to minimize the number of components for simplified treatment planning and. We launched our first oemproduct, the elos torque wrench. Tutorial about how to assemble torque wrench ev with implant driver ev. Astra tech implant system ev how to assemble torque wrench. Grade v titanium it is significantly stronger than grades i to iv titanium while having the same stiffness.
275 332 77 843 524 779 1562 1251 1447 1606 190 1331 1115 697 1548 1397 975 907 556 628 1265 809 434 1499 524 591 1002 1233 960 60 1443 1343 1267 990 211 387